“CABLE AND WIRES” JOURNAL - 2022 #3

Ссылка на номер в Научной электронной библиотеке ELIBRARY.RU


EDITOR-IN-CHIEF'S COLUMN


ON THE VERGE OF GREAT CHANGES


SCIENCE AND TECHNOLOGY   


DOI 10.52350/2072215Х_2022_3_4

ADHESION INDEX RATING OF WINDING WIRES WITH POLIIMIDE-FLUOROPLASTIC FILM INSULATION

V.K. Andrianov, Cand. Sc. (Engineering), Department Manager, OJSC VNIIKP;

E.V. Bykov, Cand. Sc. (Physics and Mathematics),Technical Director of Ltd. “Electroneftemash”;

A.A. Nogin, Engineer, Ltd. “Electroneftemash”;

N.V. Semerukhina, Department Manager, Ltd. “Electroneftemash”

Abstract. The article analyzes the factors influencing the adhesion of polyimide-fluoroplastic insulation to the copper conductor, the principles of the adhesion index rating and offers a method for its rating based on the results obtained.

Key words: polyimide-fluoroplastic insulation, adhesion, winding wires


DOI 10.52350/2072215Х_2022_3_9

HV AND EHV CABLES AND ACCESSORIES TEST EXPERIENCE

S.S. Vetlugaev, Cand. Sc. (Engineering), Senior Research Scientist, OJSC VNIIKP;

A.N. Gorobets, Cand. Sc. (Engineering), Head of Sector, OJSC VNIIKP;

L.E. Makarov, Cand. Sc. (Engineering), Leading Research Scientist, OJSC VNIIKP;

V.L. Ovsienko, Cand. Sc. (Engineering), Deputy Manager of Energy Cable and Wire Division, OJSC VNIIKP;

M.Yu. Shuvalov, Dr. Sc. (Engineering), Manager of Energy Cable and Wire Division – Director of Research Area, OJSC VNIIKP;

V.B. Pshennov, Cand. Sc. (Engineering), Technical Director of Ltd. “Izolyator-AKS”;

A.A. Filippov, Operation Engineer, Ltd. “Izolyator-AKS”

Abstract. The following test results are presented: the 220 kV joint outer protection mechanical test, including static pressure application, thermal cycling in water, d.c. and impulse voltage test; 110 kV termination low temperature test at minus 60 0C; type test of the 500 kV cable with 2500 mm2 and 3000 mm2 copper conductor. In addition the 500 kV cable was subjected to a series of lightning voltage impulses with an amplitude of up to 1850 kV at the conductor temperature of 110–115 0C without breakdown.

The tasks for the nearest future are defined – development of the national standard for HV and EHV cables and the organization of production of materials for HV cable insulation systems in Russia.

Key words: HV and EHV power cable, cable accessories, HV test, XLPE-based insulating materials, quality control, mechanical test, climatic test, national standard


DOI 10.52350/2072215Х_2022_3_17

EXPERIMENTAL EVALUATION OF THE METHOD FOR PROTECTION AGAINST OPTICAL FIBER MOVEMENT INTO SPLICE CLOSURES DURING SEASONAL TEMPERATURE FLUCTUATIONS

V.A. Burdin, Povolzhskiy State University of Telecommunications and Informatics (PSUTI), Doctor of Technical Sciences, professor;

S.A. Gavryushin, Povolzhskiy State University of Telecommunications and Informatics (PSUTI), Head of the laboratory of Dept. of Communications Lines;

M.V. Dashkov, Povolzhskiy State University of Telecommunications and Informatics (PSUTI), associate pat the Dept. of Communications Lines, Ph.D.  of Engineering Sciences, assistant professor;

A.O. Nizhgorodov, Povolzhskiy State University of Telecommunications and Informatics (PSUTI), postgraduate of Dept. of Communications Lines;

T.G. Nikulina, Povolzhskiy State University of Telecommunications and Informatics (PSUTI), associate professor at the Dept. of Communications Lines, Ph.D.  of Engineering Sciences;

B.V. Popov, Povolzhskiy State University of Telecommunications and Informatics (PSUTI), professor of Dept. of Communications Lines, Ph.D.  of Engineering Sciences, professor

Abstract. The description of the traditional and developed methods for protection from optical fiber movement in optical closures during seasonal temperature variations is represented in paper. The results of experimental testing of the developed methods demonstrating their effectiveness are provided.

Key words: optical fiber, loose tube, optical closure, splice trays, all-dielectric self-supporting cable, climatic test


DOI 10.52350/2072215Х_2022_3_26

STUDY OF THE EFFECT OF LONG-TERM OPTICAL CABLE AND FIBER EXPOSURE TO HIGH AND LOW TEMPERATURES

I.A. Ovchinnikova, Dr. Sc. (Engineering), Head of the Department of cables and wires for telecommunications and information, OJSC VNIIKP;

E.Y. Gecha, Dr. Sc. (Engineering), Chief Research Scientist, OJSC VNIIKP;

A.G. Koriakin, Ph.D. of Engineering Sc., Head of the laboratory, OJSC VNIIKP;

P.A. Semenov, engineer, OJSC VNIIKP;

V.A. Ovchinnikova, student, Moscow Technical University of Communications and Informatics;

V.A. Ovchinnikov, student, Moscow Technical University of Communications and Informatics;

N.A. Shishova, Ph.D. of Engineering Sc., Head of the dept. of Multichannel telecommunication systems, Moscow Technical University of Communications and Informatics

Abstract. The work presents the results of studies of optical fibers and optical cables during and after exposure, including long-term (more than a year), elevated and critically increased temperatures. It also shows the dependence of the attenuation coefficient in cables and fibers on the effect of negative temperatures. The impact on the resistance to these temperatures of the design has been investigated. It has been shown that optical cables and fibers are capable of long-term operation in a wide temperature range.

Key words: optical fiber, protective coating, optical cable, high temperature, low temperature, temperature cycles, attenuation, test, material, sheath


INDUSTRY NEWS


MEETING OF THE ELECTROCABLE ASSOCIATION BOARD IN SMOLENSK


JUBILEES


N.I. Gromov celebrated his 70th birthday

I.E. Kuimov celebrated his 70th birthday

V.V. Vedmed celebrated his 60th birthday

S.A. Gladkikh celebrated his 55th birthday

R.R. Abaev celebrated his 50th birthday

R.E. Vasiliev celebrated his 45th birthday

A.A. Nor celebrated his 45th birthday